Oberdorfer FIP Pump Modle# N211DE-04
These Rubber Impeller pumps are made of high quality bronze of
maximum corrosion resistance. All shafts consist of stainless steel
grade 303. Top of the line models have ball bearings and mechanical
seals while others have bronze or carbon bearings and lip type seals.
Impellers are made of Neoprene Rubber. Nitrile impellers are available
as an option. Flexible blades on the periphery of the impeller provide
the pumping action. While the impeller rotates the liquid between the
blades is continuously squeezed out into the discharge port by a
machined in cam located inside the pump chamber.
For longevity of the pump, we recommend the impeller and seal be replaced under the following guidelines:
The impeller must be replaced if it is worn out or has been damaged
by debris or by running the pump dry. Symptoms of a defective impeller
are low pumping pressure and low flow. To replace the impeller remove
screws and cover. Pull out the impeller with needle nose pliers or two
screwdrivers. Be careful not to dent the pumping chamber with these
tools. When inserting new impeller, line up key slot in impeller with
the key in the shaft. Use oil on shaft and avoid forcing the impeller
onto the shaft. The impeller should also be removed for storage periods
to prevent the blades from taking a permanent set.
If water drips from the area where the shaft exits the pump, the seal
is defective and must be replaced. While the shaft slinger barrier seal
provides a first line of defense, prolonged running of the pump with a
leaky seal can destroy the ball bearings of the electric motor. For seal
replacement, the pump must be removed from the motor and disassembled
in order to gain access to the seal area. The Nitrile seal must be
pushed out of the press-fitted position and a new lip seal pressed into
place, using a sealant on the outside of the lip seal housing. Refer to
exploded view drawings for seal location and part numbers for ordering
purposes.
FEATURES
- Bronze construction - Corrosion Resistant
- Garden hose threads (external) & pipe threads (internal) port connections
- Impeller & cam easily replaced
- Large vent openings separate pump & motor
- Motor shafts are stainless steel
- Shaft slinger protects motor bearings
- Convenient carrying handle
- Sealed and grounded 3-conductor plug-in cord
- Meets U.S. Coast Guard Ignition Protection Requirements, 33CFR 183.410(a)
- PIPE SIZE: 3/8” ID AND 3/4” OD GARDEN HOSE
DRIVE
Motor drive is clockwise facing pump end. Liquid
flow direction is right to left facing pump end - see dimension drawing.
Motor is 1/6 HP, 1725 RPM, 115VAC, TENV.
DO NOT RUN DRY - Rubber impellers generate high
rubbing friction unless lubricated by liquid being pumped. Lack of
liquid will cause impeller to burn up. Standard impeller in Neoprene
(04), optional Nitrile impeller (05) available.
LIQUIDS & TEMPERATURES
Liquids compatible with neoprene can be pumped
including fresh and salt water solutions. Do not pump severe solvents or
acids. When possible, flush pump with fresh water after each usage.
Extremes of cold and heat will affect impeller life. Limits of 40o to
180oF should be observed. Do not allow liquid in pump to freeze. Drain
pump by loosening cover screws. Use methyl alcohol based anti-freeze
compounds such as Zerex, Shell Zone, Pyro Permanent, Permaguard, and
Dowgard.
SUCTION LIFT
Suction lift to 15 ft. for model 211D is possible
when impeller is wet. Suction lines must be air tight in order for pump
to self prime. Always use foot valve at beginning of suction line to
keep suction line full and impeller wet.